Zéro CO2

GreenB + GreenH

GreenB + GreenH
GreenB+GreenH

Série GreenB + GreenH
Batterie All-in-one 100K + Onduleur hybride 50K

Sûre et Fiable
Cellule de batterie CATL LFP.
10 000 cycles de vie.
Double système d'extinction d'incendie.
1+1 Redundancy Design.

Simple et Convivial
Préinstallé en usine pour une installation facile sur site.
BMS/EMS intégré, adapté à diverses applications.
Effortless Operation, Cloud Control.

Économique et Efficace
Économise les dépenses d'investissement et s'étend selon les besoins.
Conception HVAC efficace et économe en énergie.

Spécifications

MODÉLE GreenB 100K
TECHNICAL PARAMETERS
Battery Type LFP
Battery Module Capacity 5.12 kWh
Number of Modules 10*2
Total Battery Capacity 102.4 kWh
Nominal Voltage 512 V
Operating Voltage Range 448 V ~ 565 V
Charge / Discharge Rate Maximum 0.5C
Cycles de Vie 10 000 à 90 % DoD
DoD 90%
GENERAL PARAMETERS
Dimensions (W x D x H) 1100 x 1100 x 2380 mm
Weight < 1.5 T
Installation Site Outdoor
IP Protection IP54
Anti Corrosion Level C4
Operation Humidity 5% ~ 95% (No Condensing)
Operation Temperature -30°C ~ +50°C
Maximum Operation Altitude 4000 m ( > 3000 m Derating)
Communication Port Ethernet; CAN
Communication Protocol CAN; MODBUS TCP/IP
Cooling Method Air Conditioner
Standards IEC62619-2017; UN38.3; IEC61000-6-2/4
MODÉLE GreenH 50K
PV SIDE
Maximum Input Voltage 1000 V
Maximum PV Power 75 kW
MPPT Voltage Range 350 V ~ 800 V
Maximum Current per MPPT 36 A
Number of MPPT 3
Number of Inputs Per MPPT 2
BATTERY SIDE
Maximum Input Voltage 750 V
Minimum Input Voltage 350 V
DC Voltage at Nominal Operation 500 V ~ 750 V
Maximum DC Current 50 A*2
Maximum DC Input Power 55 kW
Number of DC Inputs 2
AC SIDE (ON GRID)
Nominal AC Output Power 50 kW
Maximum AC Output Power 55 kVA
Maximum AC Current 80 A
Nominal AC Voltage 400 V
AC Voltage Range 340 V ~ 440 V
Nominal Grid Frequency / Frequency Range 50 / 60 Hz ± 5 Hz
THDv < 3% (100% Load)
Adjustable PF Range -1 (Lagging) ~ 1 (Leading)
AC SIDE (OFF GRID)
Nominal AC Voltage 230 / 400 V ± 3%; 3L + N + PE
THDv < 3% (Linear Load)
Nominal Grid Frequency / Frequency Range 50 / 60 Hz
Nominal AC Output Power 50 kW
Maximum AC Output Power 55 kVA
EFFICIENCY
Maximum Efficiency 97.5%
PROTECTION
Reverse Connection Protection Yes
DC Switch Yes
Over-Temperature Protection Yes
Grid Monitoring / Earthing Fault Detection Yes
Insulation Monitoring Yes
DC / AC Surge Protection DC Type II; AC Type II
GENERAL PARAMETERS
Dimensions (W x H x D) 650*715*325 mm
Weight 62 kg
Topology Transformerless
IP Protection IP65
Operation Temperature Range -25 ~ 60°C ( > 45°C Derating)
Operation Humidity Range 0 ~ 100% (No Condensing)
Cooling Method Intelligent Air Cooling
Maximum Operation Altitude 4000 m ( > 3000 m Derating)
Communication Port RS485 / CAN
Standards IEC 62477, IEC61000, CE, GB/T

Les caractéristiques techniques du produit sont susceptibles d'être modifiées sans préavis.