Zero CO2

Omega SPLIT Phase

Omega SPLIT Phase
Omega SPLIT Phase

OMEGA SPLIT Phase Series

Main Features
Multiple output of 120 V / 240 V Split phase, 120 V Single phase or 120 V / 208 V split phase.
IP65, depending on the model, waterproof and dustproof for various working conditions.
Self-consumption and Feed-in to the grid.
Built-in alternative port for generator and emergent load.
Optional external CT sensor to guarantee 100% self-consumption.
Built-in communication port for BMS (RS-485) and Wi-Fi.
Programmable multiple operation modes: Grid-tie, off-grid and gridtie with backup.
Parallel operation up to 9 units, depending on the model.

SOLUTIONS

+THINK +CONSTRUCT

Specifications

MODELS Omega WP LV 6K Omega V7 LV 6K
DATA SHEET
Phase 120 V / 240 V Split phase, 120 V / 208 V Split phase Split phase
Maximum PV Input Power 7500 W 6000 W
Rated Output Power 6000 VA / 6000 W 6000 VA
Maximum Charging Power 6000 W 5000 W
GRID-TIE OPERATION
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage 600 VDC 360 VDC / 450 VDC
Start-up Voltage / Initial Feeding Voltage 120 VDC / 160 VDC 110 VDC / 120 VDC
MPP Voltage Range 120 VDC ~ 550 VDC 120 VDC ~ 430 VDC
Number of MPP Trackers / Maximum Input Current 2 / 15 A 1 / 27 A
GRID OUTPUT (AC)
Nominal Output Voltage 120 VAC (P-N), 208 VAC (P-P), 240 VAC (P-P) 110-120 VAC (L-N) / 220-240 VAC (L1-L2)
Output Voltage Range 105.5 VAC - 132 VAC (per phase) 93.5 - 126.5 VAC for 110 VAC; 102 -138 VAC for 120 VAC
Nominal Output Current 25 A per phase 27.3 A para 110 VAC, 25 A para 120 VAC
Power Factor 0.9 lag to 0.9 lead > 0.99
No Load Consumption 75 W
EFFICIENCY
Maximum Conversion Efficiency (DC/AC) 96% 95%
OFF-GRID, HYBRID OPERATION
PV INPUT (DC)
Nominal DC Voltage / Maximum DC Voltage 600 VDC 360 VDC / 450 VDC
Start-up Voltage / Initial Feeding Voltage 120 VDC / 160 VDC 110 VDC / 120 VDC
MPP Voltage Range 120 VDC ~ 550 VDC 120 VDC ~ 430 VDC
Number of MPP Trackers / Maximum Input Current 2 / 15 A 1 / 27 A
AC INPUT
AC Start-up Voltage / Auto Restart Voltage 85 VAC (per phase) / 90 VAC (per phase) 65 VAC (P-N), 130 VAC (P-P) / 70 VAC (P-N), 140 VAC (P-P)
Acceptable Input Voltage Range
85 - 140 VAC (per phase) 65 - 140 VAC (Appliances) or 95 - 140 VAC (Personal computer)
Maximum AC Input Current 40 A per phase
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage 120 VAC (P-N), 208 VAC (P-P), 240 VAC (P-P) 110 - 120 VAC (L-N) / 220 - 240 VAC (L1-L2)
Output Waveform Pure sine wave
Efficiency (DC to AC) 91% 93%
BATTERY & CHARGER
DC Voltage Range / Nominal Voltage 40 - 62 VDC / 48 VDC 48 VDC
Maximum Solar Charging Current
120 A
Maximum AC Charging Current
120 A
Maximum Charging Current 120 A
GENERAL
PHYSICAL
Dimension, (D x W x H)
215.5 x 515 x 700 mm 138.4 x 365 x 593.6 mm
Net Weight
41 kg 26 kg
INTERFACE
Parallel Function 6 units Up to 9 units
Communication Port RS232, RS485, WI-FI, USB USB / RS-232 / RS-485 / Wi-Fi / / Dry contact
ENVIRONMENT
Humidity 0 ~ 90% RH (Non-condensing)  
Operating Temperature -25°C to 60°C ( > 45°C derating) -10°C to 50°C
STANDARD
Protection Degree IP65  
Safety UL1741SA, UL1741SB, CSA 22.2.107.1, CEC, CRD  
Grid Connection Standard
IEEE1547.1-2020  
EMC FCC CRF47 PART15 B  

Product specifications are subject to change without further notice.