Electric Vehicles Series
Main Features
• Input power factor correction 0.99.
• High efficiency up to 94.6%.
• Wide input voltage range suits different power environment.
• Wide operation temperature (-30°C ~ 65°C) withstand harsh environment.
• Parallel operation without limitation.
• Supports CAN communication.
Specifications
| MODEL | Omega EV 15KW | |
|---|---|---|
| Capacity | 15 kW | |
| AC INPUT |
Nominal Input Voltage | 3 - Phase 380 VAC |
| Acceptable Input Voltage Range | 304 ~ 496 VAC @ full load 260-304 VAC @ linear derating to 6KW |
|
| Working Voltage Range | 260 ~ 486 VAC | |
| Maximum Input Current | 33 A | |
| Frequency Range | 45 ~ 65 Hz | |
| Input Power Factor | > 0.99 @ nominal input and full load output > 0.98 @ nominal input and half load output |
|
| THDi | < 5% @ nominal input and full load output < 10% @ nominal input and half load output |
|
| Soft Startup Time | 5 ~ 15 S | |
| DC OUTPUT |
DC Output Voltage Range | 300 ~ 750 VDC |
| Nominal Output Current | 20 A, 2 ~ 25 A adjustable | |
| Efficiency | 94.6% | |
| Voltage Regulation Precision | ± 0.5% | |
| Current Regulation Precision | ≤ ±1 | |
| Current Sharing Difference | 5% @ > 50% load on each UPS | |
| PROTECTION | Input Over Voltage Protection | 496 ± 5 VAC |
| Input Under Voltage Protection | 255 ± 5 VAC | |
| Output Over Voltage Protection | 757.5 ± 2.5 VDC | |
| Output Under Voltage Protection | 100 VDC | |
| Full Protection | Over-temperature protection, input current unbalanced protection, input current protection, output current protection and output soft startup protection |
|
| PHYSICAL | Dimension, D x W x H | 455 x 230 x 85 mm |
| Net Weight | 10 kg | |
| ENVIRONMENT | Humidity | 5 ~ 95% Relative Humidity (Non-condensing) |
| Operating Temperature | -30° ~ 65°C (output derating @ 50°C ~ 65°C) | |
| MANAGEMENT | Communication | CAN |