Beta RHI 6K-48ES-5G Series
Main Features
• Uninterrupted power supply, 20ms reaction.
• Compatible with both lead-acid battery and li-ion battery.
• Compatible with any existing grid-tied PV system, option to upgrade.
• Off-grid backup function.
• EPS function.
• Intelligent EMS function.
• Intelligent debugging APP which support one-click inverter configuration.
• CAN, RS-485 (Optional).
• Various work mode for different application scenario.
• Natural cooling without external fan.
SOLUTIONS
+THINK +CONSTRUCT
Specifications
| MODEL | Beta RHI-6K-48ES-5G | |
|---|---|---|
| INPUT DC (PV SIDE) | ||
| Recommended Maximum PV Power (kW) | 8 | |
| Maximum Input Voltage (V) | 600 | |
| Rated Voltage (V) | 330 | |
| Start-Up Voltage (V) | 120 | |
| MPPT Voltage Range (V) | 90 - 520 | |
| Maximum Input Current (A) | 14 +14 | |
| Maximum Short Circuit Current (A) | 17.2 / 17.2 | |
| MPPT Number / Maximum Input Strings Number | 2 / 2 | |
| BATTERY | ||
| Battery Type |
Li-ion / Lead-acid | |
| Battery Voltage Range (V) | 42 - 58 | |
| Battery Capacity (Ah) | 50 - 2000 | |
| Maximum Charge / Discharge Power (kW) | 5 | |
| Maximum Charge / Discharge Current (A) | 100 | |
| Communication | CAN / RS-485 | |
| OUTPUT AC (BACK-UP) | ||
| Rated Output Power (kW) |
5 | |
| Maximum Apparent Output Power (kVA) | 6 | |
| Back-Up Switch Time | < 20 ms | |
| Rated Output Voltage (V) | 1 / N / PE, 220 / 230 | |
| Rated Frequency (Hz) | 50 / 60 | |
| Rated Output Current (A) | 22.7 / 22 | |
| THDv (Linear Load) | 2% | |
| INPUT AC (GRID SIDE) | ||
| Input Voltage Range (V) |
184 - 264 | |
| Maximum Input Current (A) | 26.1 | |
| Frequency Range (Hz) | 45 - 55 / 55 - 65 | |
| OUTPUT AC (GRID SIDE) | ||
| Rated Output Power (kW) |
6 | |
| Maximum Apparent Output Power (kVA) | 6 | |
| Operation Phase | 1 / N / PE | |
| Rated Grid Voltage (V) | 220 / 230 | |
| Rated Grid Frequency (Hz) | 50 / 60 | |
| Rated Grid Output Current (A) | 27.2 / 26.1 | |
| Maximum Output Current (A) | 26.1 | |
| Power Factor | > 0.99 (0.8 leading - 0.8 lagging) | |
| THDi | ||
| EFFICIENCY | ||
| Maximum Efficiency |
> 97.5% | |
| EU Efficiency | > 96.8% | |
| PROTECTION | ||
| Ground Fault Monitoring |
Yes | |
| Integrated AFCI (DC arc-fault circuit protection) | Yes | |
| DC Reverse-Polarity Protection | Yes | |
| Protection Class / Over Voltage Category | I / III | |
| GENERAL DATA | ||
| Dimensions (W*H*D) (mm) |
333*505*249 | |
| Weight (kg) | 17 | |
| Topology | High frequency isolation (for battery) | |
| Operating Ambient Temperature Range | -25 ~ 60°C | |
| Ingress Protection | IP65 | |
| Cooling Concept | Natural convention | |
| Maximum Operation Altitude | 2000 m | |
| Grid Connection Standard | G98 or G99, VDE-AR-N 4105 / VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019, RD 1699 / RD 244 / UNE 206006 / UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA |
|
| Safety / EMC Standard | IEC / EN 62109-1/-2, EN 61000-6-2/-3 | |
| FEATURES | ||
| DC Connection |
MC4 connector | |
| AC Connection | Quick connection plug | |
| Display | 7.0"LCD color screen display | |
| Communication | RS-485, Optional: Wi-Fi, GPRS | |
Product specifications are subject to change without further notice.