Zero CO2
+34 91 802 16 49 info@masterbattery.es

Beta 80K-5G

Beta 80K-5G
Beta (80-100)K-5G

Beta 80K-5G Series

Main Features
•  13 A per string, 150% DC overload capacity..
•  9 individual MPPT, lower loss of production.
•  Efficient logic algorithm, more than 99% max.
•  FV module chain monitoring, shorter O&M time.
•  Remote and local intelligent IV scanning function.
•  Leakage current repression technology.
•  Volt-watt work mode integrated.
•  DC input reverse alarm.
•  Optional anti-PID function integrated.
•  Reactive power compensation function.

Specifications

MODEL Beta 80K-5G
INPUT DC
Maximum Recommended DC Input Power (kW) 112
DC Input Voltage (V) 1100
Nominal DC Voltage (V) 600
Output Voltage (V) 200
MPPT Operating Voltage Range (V) 180 - 1000
Full Load MPP Voltage Range (V) 505 - 850
Maximum Input Current (A) 26*8
Maximum Short-Circuit Current for each MPPT (A) 40*8
MPPT Number / Maximum Input Strings Number 8/A:2; B:2; C:2; D:2; E:2; F:2; G:2; H:2
OUTPUT AC
Rated Output Power (kW)
80
Maximum Apparent Output Power (kVA) 88
Maximum Output Power (kW) 88
Nominal Grid Voltage (V) 230 / 400
Nominal Grid Frequency (Hz) 50 / 60
AC Grid Frequency Range (Hz) 45 ~ 55 / 55 ~ 60
Operation Phases Three
Nominal Grid Output Current (A) 115.5
Output Current (A) 133.7
Power Factor (nominal output power) 0.8 Leading... 0.8 Lagging
THDi (nominal output power) < 3%
DC Injection Current 0.5% In
EFFICIENCY
Maximum Efficiency 99.0%
EU Efficiency 98.4%
MPPT Efficiency 99.5%
PROTECTION
Islanding Protection
Yes
DC Reverse-Polarity Protection Yes
Isolation Resistance Monitoring Yes
Residual Current Detection Yes
DC Overvoltage Protection Type II / Type I + II
AC Overvoltage Protection Type II
Grid Monitoring Yes
Strings Monitoring Yes
I / V Curve Scanning Yes
Anti-PID Function Yes
Integrated AFCI (DC arc-fault circuit protection) Yes
Integrated DC Switch Yes
Integrated AC Switch Optional
GENERAL DATA
Dimensions (mm)
1050W*567H*286.5D
Weight (kg) < 85
Topology Transformerless
Self Consumption (night) < 2W
Operating Ambient Temperature Range -25 ~ 60°C
Relative Humidity 0 ~ 100%
IP Protection IP66
Noise Emission (typical) ≤ 55 dBA
Cooling Concept Intelligent redundancy fan
Maximum Operation Altitude 4000 m
STANDARDS
Grid Connection Standard
EN50549, G99, AS4777.2-2015, VDE0126-1-1, IEC62727, VDE4105-2018, IEE1547, UL1741SA
Safety / EMC Standard IEC62109-1/-2, NB/T32004-2018, EN61000-6-1, EN61000-6-3, UL1741, FCC
FEATURES
DC Connection MC4
AC Connection OT Terminal connectors
Display LCD, 2 × 20 Z.
Communication Connections RS485 / PLC (optional)
Warranty 5 / 10 / 15 / 20 Years

Product specifications are subject to change without further notice.