Zero CO2

Beta 30K-5G

Beta 30K-5G
Beta 30K-5G

Beta 30K-5G Series

Main Features
•  Over 98.8% Max. effciency.
•  Wide voltage range and low startup voltage.
•  3 MPPT design with precise MPPT algorithm.
•  THDi < 3%, low harmonic distortion against grid.
•  Anti-resonance, single transformer can connect 6M+ in parallel.
•  Perfect commercial site monitoring solution.
•  130% DC overload ratio, 13A input for each PV string.
•  Strings intelligent monitoring, Smart I-V Curve Dignosis supported.
•  Fuse free design to avoid fire hazard.
•  Type II surge arrester for both DC and AC.
•  Natural convection, Fan-less design, longer lifespan.
•  Leakage current repression technology.
•  Volt-watt work mode integrated.
•  DC input reverse alarm.
•  Intergrated Export Power Manager (EPM).

Specifications

MODEL Beta 30K-5G
INPUT DC
Maximum Input Power (kW) 39
Maximum Input Voltage (V) 1100
Rated Voltage (V) 600
Start-Up Voltage (V) 180
MPP Voltage Range (V) 200 - 1000
Maximum Input Current (A) 26 + 26 + 26
Maximum Short-Circuit Current (A) 40 + 40 + 40
MPPT Number / Maximum Input Strings Number 3 / A: 2; B: 2; C: 2
OUTPUT AC
Rated Output Power (kW)
30
Maximum Apparent Output Power (kVA) 33
Maximum Output Power (kW) 33
Rated Grid Voltage (V) 3 / N / PE, 220 / 380, 230 / 400
Rated Grid Frequency (Hz) 50 / 60
Rated Grid Output Current (A) 45.6 / 43.3
Maximum Output Current (A) 50.2
Power Factor > 0.99 (Adjustable from 0.8 leading to 0.8 lagging)
THDi < 3%
EFFICIENCY
Maximum Efficiency 98.8%
EU Efficiency 98.3%
PROTECTION
DC Reverse-Polarity Protection
Yes
Short Circuit Protection Yes
Output Over Current Protection Yes
Surge Protection DC Type II / AC Type II
Grid Monitoring Yes
Anti-islanding Protection Yes
Temperature Protection Yes
Strings Monitoring Yes
I / V Curve Scanning Yes
Anti-PID Function Optional
Integrated DC Switch Optional
GENERAL DATA
Dimensions (W*H*D*)
647*629*252 mm
Weight (kg) 45
Topology Transformerless
Self Consumption < 1W (Night)
Operating Ambient Temperature Range -25 ~ 60°C
Relative Humidity 0 ~ 100%
Ingress Protection IP65
Cooling Concept Convección Natural
Maximum Operation Altitude 4000 m
STANDARDS
Grid Connection Standard
EN50549, G99, AS4777.2-2015, VDE0126-1-1, IEC62727, VDE4105-2018, NB/T 32004
Safety / EMC Standard IEC62109-1/-2, EN61000-6-2, EN61000-6-3
FEATURES
DC Connection MC4 connector
AC Connection Terminal OT
Display LCD, 2 × 20 Z
Communication RS485; WiFi / GPRS (optional)

Product specifications are subject to change without further notice.