Zero CO2
+34 91 802 16 49 info@masterbattery.es

Beta 1P (2.5-6)K-4G

Beta 1P (2.5-6)K-4G
Beta 1P (2.5-6)K-4G

Beta 1P (2.5-6)K-4G Series

Main Features
•  Maximum efficiency 97.7%.
•  String current up to 14 A.
•  Super high frequency switching technology.
•  Wide voltage range and low startup voltage.
•  2 MPPT design with precise MPPT algorithm.
•  Integrated Export Power Manager (EPM).
•  AFCI protection, proactively reduces fire risk.
•  Compact and lightweight.
•  Friendly and adaptable connection to the grid.

Specifications

MODEL Beta
1P2.5K-4G
Beta
1P3K-4G
Beta
1P3.6K-4G
Beta
1P4K-4G
Beta
1P4.6K-4G
Beta
1P5K-4G
Beta
1P6K-4G
INPUT DC
Recommended Maximum PV Power (kW) 3.75 4.5 5.4 6 6.9 7.5 9
Maximum Input Voltage (V) 550 600
Rated Voltage (V) 250 330
Start-up Voltage (V) 60 120
MPPT Voltage Range (V) 50 - 450 90 - 520
Maximum Input Current (A) 14/14
Maximum Short Circuit Current (A) 22/22
MPPT Number/Maximum Input Strings Number 2/2
OUTPUT AC
Rated Output Power (kW)
2.5 3 3.6 4 4.6 5 6
Maximum Apparent Output Power (kVA) 2.8 3.3 4 4.4 5 5 6
Maximum Output Power (kW) 2.8 3.3 4 4.4 5 5 6
Rated Grid Voltage (V) 1/N/PE, 220 /230
Rated Grid Frequency (Hz) 50/60
Rated Grid Output Current (A) 11.4/10.9 13.6/13 16/15.7 18.2/17.4 20.9/20 22.7/21.7 27.3
Maximum Output Current (A) 13.3 15.7 16 21 23.8 25 27.3
Power Factor
>0.99 (0.8 leading - 0.8 lagging)
THDi < 3%
EFFICIENCY
Maximum Efficiency
97.3% 97.3% 97.6% 97.7%
EU Efficiency 96.5% 96.6% 97.1% 97.1%
PROTECTION
DC Reverse-polarity Protection Yes
Short Circuit Protection Yes
Output Over Current Protection
Yes
Surge Protection Yes
Grid Monitoring Yes
Anti-islanding Protection Yes
Temperature Protection Yes
Integrated AFCI (DC arc-fault circuit protection)
Yes(1)
Integrated DC Switch Optional
GENERAL DATA
Dimensions, W x H x D (mm)
310 x 543 x 160
Weight (kg) 11 11.2 12
Topology Transformerless
Self-consumption (Night)
< 1W
Operating Ambient Temperature Range
-25°C ~ 60°C
Relative Humidity 0 - 100%
Ingress Protection
IP66
Cooling Concept Natural convection
Maximum Operation Altitude
4000 m
Grid Connection Standard G98(2) or G99, VDE-AR-N 4105 / VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019, RD 1699 / RD 244 / UNE 206006 / UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA
Safety / EMC Standard IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-3
FEATURES
DC Connection
MC4 connector
AC Connection Quick connection plug
Display LCD
Communication RS-485, Optional: Wi-Fi, GPRS

(1) Activation required.

(2) G98 for 2.5 K - 3.6 K.

Product specifications are subject to change without further notice.