Beta 1P (2.5-6)K-4G Series
Main Features
• Maximum efficiency 97.7%.
• String current up to 14 A.
• Super high frequency switching technology.
• Wide voltage range and low startup voltage.
• 2 MPPT design with precise MPPT algorithm.
• Integrated Export Power Manager (EPM).
• AFCI protection, proactively reduces fire risk.
• Compact and lightweight.
• Friendly and adaptable connection to the grid.
Specifications
MODEL | Beta 1P2.5K-4G |
Beta 1P3K-4G |
Beta 1P3.6K-4G |
Beta 1P4K-4G |
Beta 1P4.6K-4G |
Beta 1P5K-4G |
Beta 1P6K-4G |
|
---|---|---|---|---|---|---|---|---|
INPUT DC | ||||||||
Recommended Maximum PV Power (kW) | 3.75 | 4.5 | 5.4 | 6 | 6.9 | 7.5 | 9 | |
Maximum Input Voltage (V) | 550 | 600 | ||||||
Rated Voltage (V) | 250 | 330 | ||||||
Start-up Voltage (V) | 60 | 120 | ||||||
MPPT Voltage Range (V) | 50 - 450 | 90 - 520 | ||||||
Maximum Input Current (A) | 14/14 | |||||||
Maximum Short Circuit Current (A) | 22/22 | |||||||
MPPT Number/Maximum Input Strings Number | 2/2 | |||||||
OUTPUT AC | ||||||||
Rated Output Power (kW) |
2.5 | 3 | 3.6 | 4 | 4.6 | 5 | 6 | |
Maximum Apparent Output Power (kVA) | 2.8 | 3.3 | 4 | 4.4 | 5 | 5 | 6 | |
Maximum Output Power (kW) | 2.8 | 3.3 | 4 | 4.4 | 5 | 5 | 6 | |
Rated Grid Voltage (V) | 1/N/PE, 220 /230 | |||||||
Rated Grid Frequency (Hz) | 50/60 | |||||||
Rated Grid Output Current (A) | 11.4/10.9 | 13.6/13 | 16/15.7 | 18.2/17.4 | 20.9/20 | 22.7/21.7 | 27.3 | |
Maximum Output Current (A) | 13.3 | 15.7 | 16 | 21 | 23.8 | 25 | 27.3 | |
Power Factor |
>0.99 (0.8 leading - 0.8 lagging) | |||||||
THDi | < 3% | |||||||
EFFICIENCY | ||||||||
Maximum Efficiency |
97.3% | 97.3% | 97.6% | 97.7% | ||||
EU Efficiency | 96.5% | 96.6% | 97.1% | 97.1% | ||||
PROTECTION | ||||||||
DC Reverse-polarity Protection | Yes | |||||||
Short Circuit Protection | Yes | |||||||
Output Over Current Protection |
Yes | |||||||
Surge Protection | Yes | |||||||
Grid Monitoring | Yes | |||||||
Anti-islanding Protection | Yes | |||||||
Temperature Protection | Yes | |||||||
Integrated AFCI (DC arc-fault circuit protection) |
Yes(1) | |||||||
Integrated DC Switch | Optional | |||||||
GENERAL DATA | ||||||||
Dimensions, W x H x D (mm) |
310 x 543 x 160 | |||||||
Weight (kg) | 11 | 11.2 | 12 | |||||
Topology | Transformerless | |||||||
Self-consumption (Night) |
< 1W | |||||||
Operating Ambient Temperature Range |
-25°C ~ 60°C | |||||||
Relative Humidity | 0 - 100% | |||||||
Ingress Protection |
IP66 | |||||||
Cooling Concept | Natural convection | |||||||
Maximum Operation Altitude |
4000 m | |||||||
Grid Connection Standard | G98(2) or G99, VDE-AR-N 4105 / VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15 / VFR:2019, RD 1699 / RD 244 / UNE 206006 / UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA | |||||||
Safety / EMC Standard | IEC/EN 62109-1/-2, IEC/EN 61000-6-2/-3 | |||||||
FEATURES | ||||||||
DC Connection |
MC4 connector | |||||||
AC Connection | Quick connection plug | |||||||
Display | LCD | |||||||
Communication | RS-485, Optional: Wi-Fi, GPRS | |||||||
(1) Activation required.
(2) G98 for 2.5 K - 3.6 K.
Product specifications are subject to change without further notice.